INSTRUMENT HANDBOOK
DeviceNet VP51
Digital Proportional Control Valve
To download the product EDS file visit www.odva.org
DeviceNet VP51 Manual Ver. 1, 22/09/03
Przeglądanie stron 0
1 2 3 4 5 6 ... 10 11

Podsumowanie treści

Strona 1 - DeviceNet VP51

1 INSTRUMENT HANDBOOK DeviceNet VP51 Digital Proportional Control Valve To download the product EDS file visit www.odva.org

Strona 2 - Warranty

10 Changing MACID or Baud Rate From Normal Operating Mode When the Device is in normal operating mode (i.e. communicating on DeviceNet), the baud r

Strona 3 - 3=Exhaust Port

11 8. EC DECLARATION OF CONFORMITY The DeviceNet VP51 Digital Proportional Valve complies with the EC Pressure Equipment Directive and the generic

Strona 4 - 5. INSTALLATION

2 Table of Contents 1. Introduction 2. Safety 3. Operating Description 4. Dimensional Details 5. Installation • Pneumatic • Electrical •

Strona 5 - DeviceNet Installation

3 3. OPERATING DESCRIPTION The DeviceNet VP51 is a programmable electronic proportional control valve. The pneumatic section is a diaphragm actua

Strona 6

4 5. INSTALLATION Pneumatic Installation • Supply Pressure: 15psig above maximum output required (200psig max.) • Output Pressur

Strona 7

5 DeviceNet Installation • Download the DeviceNet VP51 EDS file from www.odva.org • Register the EDS file using a DeviceNet configuration tool

Strona 8 - Pressure, bar

6 6. DEVICENET INTERFACE DETAILS I/O Data Name I/O Type (see Note 1) No. Bytes Format Demand Pressure Polled Output 2 12 bit integer (0 to 409

Strona 9

7 Parameter No. Name Format Default Value Class Id Instance Id Attribute Id Byte length 4 Actual Pressure Read only integer, 0-4095 0 = minimum (z

Strona 10

8 Fig. 1 - Speed Setting Effects at default Proportional and Integral Gain024681012TimePressure, bar Fig. 2 - Proportional Gain Effects at default

Strona 11

9 7. LOCAL USER INTERFACE DETAILS The DeviceNet VP51 includes an integral keypad and LCD display. During normal operation, this will display the c