N/AL.8.240.300.04 7/97
B64G
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Service Kits
Item Type Part Number
Service kit
Relieving 4383-200
Non relieving 4383-201
5 µm 4338-01
Replacement elements 25 µm 4338-99
40 µm 4338-02
Replacement Sight Glass
Prismatic (standard) 4380-040
Pyrex 4380-041
Replacement Drains
Automatic 3000-97
Manual 684-84
Service kit includes diaphragm assembly, valve assembly,
valve spring, louvre o-ring, bowl o-ring, drain seal.
143 (5.63)
114 (4.49)
8,2 (0.32)
85 (3.35)
11 (0.43)
14,5 (0.57)
93 (3.66)
30,5 (1.20)
48 (1.89)
110 (4.33)
Bracket Mounting
Use 8 mm (5/16
"
) screws to mount bracket to wall.
Bracket Kit Reference
Item Part Number
Wall Bracket 74504-50